Imagine Optic develops and manufactures the precision Shack-Hartmann HASO wavefront sensors industry leaders have come to depend on for fast, accurate results.
Our Shack-Hartmann wavefront sensors combine precision with a wide range of measurement possibilities to offer the perfect response to professionals involved in research and industrial development.
| |
Key
functionalities of the ensemble
of our HASO product line include: |
|
- Unequalled rapport between accuracy and dynamic ratio
- Absolute measurement with no need for a reference beam
- Simultaneous measurement of both phase and intensity
- Possibility to measure highly convergent or divergent beams
- Achromatic, indifferent to coherence
- Real-time measurement with no sensibility to external vibrations
- Direct beam measurement
| |
Key
features include (depending on
the model and your configuration): |
|
- From λ/100 up to λ/1000 accuracy
- Dynamic range up to 1500 λ
- Intrinsic lateral resolution from 114µm to 450µm
- From 256 up to more than 16,000 points of spatial resolution
- Speeds up to 950Hz (depending on your configuration)
Click on the product name in the table to view the product page.
|
|
|
|
|
|
|
| HASO3 32 |
32x40 |
4.9x6.1 |
λ/100
520λ |
R1 or
R2 |
50 |
FireWire |
| HASO3 42 |
42x52 |
4.8x5.9 |
λ/100
600λ |
R13 |
50 |
FireWire |
| HASO3 76 |
76x100 |
8.7x11.4 |
λ/100
1200λ |
R1 or
R2 |
Max 16 |
FireWire, CamLink |
| HASO3 128 |
128x128 |
14.6x14.6 |
λ/100
1500λ |
R1 or
R2 |
Max 7.5 |
FireWire, CamLink |
| HASO Fast |
16x16 |
2.5x2.5 |
λ/100
120λ |
R1 |
950 |
LVDS |
| HASO3 WSR 32(1) |
32x40 |
4.9x6.1 |
λ/100
520λ |
400-800nm
or
532-1064nm |
50 |
FireWire |
| HASO3 WSR 58(2) |
58x74 |
8.9x11.3 |
λ/100
1000λ |
400-800nm
or
532-1064nm |
Max 16 |
FireWire, CamLink |
| HASO HP 26 |
26x26 |
12x12 |
λ/1000
250λ |
405nm |
7.5 |
FireWire, CamLink |
| HASO3 OEM |
32x40 |
3.6x4.8 |
λ/100
400λ |
Mono in
400-1100nm |
30 |
FireWire |
| HASO NIR |
32x40 |
3.6x4.8 |
λ/35
400λ |
1500-1600nm |
30 |
FireWire |
| HASO UV |
50x50 |
8x8 |
λ/75
2000λ |
193-300nm |
20 |
CamLink |
| HASO X-EUV |
50x50 |
20x20 |
λ/100
5000λ |
7-25nm
(50-200 eV) |
0.5 |
PCI board |
| 1) Available first quarter 2007. 2) Available second quarter 2007. 3) R1 = range 400-600nm/500-700nm/650-900nm/800-1100nm. 4) R2 = extended range 400-700nm/500-900nm/650-1100nm. 5) Hartmann micro-hole array. |
If you would like more information on our HASO wavefront
sensor product line, please call us at +33 (0)1 64 86
15 60 or contact . |
|