Our HASO Fast Shack-Hartmann wavefront sensors provide fast accurate and reliable measurements by uniting the standard HASO family’s standard functionalities that customers have come to rely on, including absolute measurement, unequalled accuracy and insensitivity to vibration, with an acquisition speed of 950 Hz and a spatial resolution of 16 x 16 microlenses.
Our proprietary Dynamic Spot Tracking™ and Auto Spot Finder™ features combined with the exceptional optical quality of our refractive microlenses in our patented Rotated Square™ configuration provide superior accuracy and eliminate crossing spots, without compromising dynamic range. Even more, Imagine Optic’s proprietary calibration technology enables you to obtain absolute measurements every time, without the need for a reference beam, and our patented sensor design allows you to measure phase and intensity independently and in real-time.
When coupled with our HASO v3 software package, you can perform both zonal and modal wavefront reconstruction; calculate the PSF, MTF and Strehl ratio; visualize the spot diagram; and obtain the M² parameter. Adaptive optics users can take advantage of our CASAO™ software package to control adaptive optics loops to compensate for atmospheric turbulence, optimize the focal spots of laser beams and Freespace communications.
If you would like more information on our products, please call +33 (0)1 64 86 15 60 or e-mail us at .
|
|

|
| Aperture dimension |
2,5 x 2,5 mm2 |
| Sub-apertures dedicated for analysis (1) |
16 x 16 |
| Refractive microlens technology |
standard square |
| Tilt dynamic range |
> ± 3 ° |
| Focus dynamic range - minimum local radius of curvature |
± 0,025 m |
| Focus dynamic range - maximum n.a. |
0.1 |
| Repeatability (rms) |
< λ/200 |
| Wavefront measurement accuracy in absolute mode (rms) (2) |
~ λ/100 |
| Wavefront measurement accuracy in relative mode (rms) (3) |
~ λ/150 |
| Tilt measurement accuracy (rms) |
6 µrad |
| Focus measurement accuracy (rms) |
5x10-3 m-1 |
| Spatial resolution |
~ 160 μm |
| Maximum acquisition frequency |
955 Hz |
| Processing frequency |
800 Hz |
| Working wavelength |
350-1100 nm |
| Calibrated wavelength range |
On request |
| Extended calibrated wavelength range |
On request |
| Working temperature |
15 – 30° |